AMC - Fire Protection Systems Maintenance( 01 Jan - 31 Dec 2024)



Contract Posted On: April 5, 2024 Closing On: April 21, 2024 Scope of Work – Fire Protection System Maintenance Service Frequency: Common Area service – Quarterly ( 4 times/ Year ) Shell and core offices - Quarterly ( 4 times/Year )
Inside Apartment Services - Half Yearly ( 2 times / Year ) Emergency Callouts- Unlimited FACP Programming - Unlimited, included in service DCD Attestation: Yearly DCD attestation Fees shall be included in the offer. AMC attestation shall be completed immediately upon the healthy status of the Fire Protection systems in the building. Consumables and Spare Parts: Non-Comprehensive Requirements during the tenure shall be quoted separately with the best quality and competitive market rate. Maintain a reasonable inventory of essential spare parts for maintenance and services falling within the scope of services. PPM consumables shall be included in the service. Emergency Response: Priority 1 – Emergency: Immediately (Within 1 hour ) Incident requires urgent interference e.g. Fire incident, Water leakage, Frequent Fire alarms, etc. Priority 2 – Urgent: Within 2 hours Poses a threat of personal injury, equipment damage, or serious disruption of operations. Priority 3 – Expedited: 8 Hours Something that is not classified as urgent but needs to be resolved speedily e.g. a situation that reflects poorly on the Client. Priority 4 – Scheduled: 24 Hours Nonurgent to operations. Date scheduled, chargeable works requiring prior client approval Note: Technical assistance via phone calls shall be provided to the building security or FM the team immediately if required. Scope of Work: Fire Alarm System Checking the condition of the panels. Check the Logbook entries since the last visit and ensure that appropriate action is taken. Test the Uninterrupted Power Supply for both cases by removing: Main power supply. Batteries and checking all fault signal display Check battery charges for correct output voltage and current. Creating alarms on each loop and check the response. Check all main units for signs of deteriorating due to adverse environmental conditions. Checking sensitivity where applicable Checking the dirtiness of the smoke detectors and clean the necessary. Check Smoke & Heat Detectors at each visit for correct operation to ensure that all detectors are tested annually 4 times. Checking line-continuity for all lines supporting detectors that cannot be activated without occurring damage to them. Checking the manual call points and alarm sounder. Checking the response of other systems connected to the fire alarm system. Checking the messages for all detectors and update the system necessary. Checking the network between all control panels. Testing the response for fire alarm system with other interfaced systems, such as sprinkler system. Ensure that there is sufficient spare Break Glass available on site. Ensure that all devices are recognized correctly by the location of the panel. Ensure that any device replacement is correctly programmed in the panel. Check that there have been no changes to the premises which would adversely affect the protection provided by the system. Maintain up-to-date programming and system of the panel . Portable Fire Extinguishers
Check the extinguishing medium and applied pressure and refill when needed. Check extinguisher body for corrosion/ physical damage. Check the mechanical functions of all valves/components and lubricate if required. Check if the extinguishers are in the designated places. Check the lever/handle/ Lock/valves for mechanical functions. Check extinguisher gauge/cartridge. Check the hose condition. Check the weight of the extinguisher Refill the extinguisher up to 2 times a year as needed. Fit a sticker to all extinguishers indicating the inspection date and provision/comments. Assure extinguisher nozzle/horn is tight, the extinguisher is clean, and seals are intact. Ensure the signages on extinguishers are intact and easy to identit y. Hose Reel System Check Fire Hose Connection for any damages Check if the valves the handle is missing. Inspect the valve for any leak and rectify it. Make sure the hose is connected properly. Ensure the nozzle is not missing and operating smoothly. Check nozzle mechanism Check if the hose is damaged or not rolled properly Run out the hose and check Discharge water for pressure rating Check pumps response, i.e. When operated causing pressure drop, the pump should start automatically. Emergency Lights & Exit Signs Maintain the Central Storage Battery Emergency Lights and Exit Sign Panels. Inspect Each Emergency Light and Exit Sign for functionality Replace defective Lamps and rectify the faults, if any. Check the storage Battery's physical condition and connections. Check the storage Battery Charging system. Test Emergency Lights for at least 3 minutes on each visit and at least for 90minutes annually with an ac power interruption. Fire Pump & Control Panel Check the fire pump a system including pipework, joints, and fitting visually to ensure that the device/system appears to be a normal and operational condition. Check for corrosion and paintwork Check pump motor set, mounting, bearing, and leakage Record the pressure on Fire Pump Gauges at the Discharge line and suction line Check all the Valves Gauges & Flow switches for their respective open/close position and leakages. Check flow switches Pump run timers Lubricate the pump bearing, coupling, and mechanical parts if necessary Grease motor bearing Checking of cooling the system, exhaust systems for normal operations Check and exercise all valves Check for automatic indication of controller lights Check the healthiness of the control panel, it’s fuses, relays, other electrical components, and operations Reset the activated alarms (if any) on the fire panel and restore the system to normal Ensure all inlet/outlet valves and zone control valves are open and have a chain –lock arrangement in place. Check the Main Panel response when pumps are operated. Fire Suppression Systems Check-up the operation of both zones smoke detectors Check-up the functioning of Releasing/actuating circuits Check-up the functioning of Abort/ Manual Release Switches. Check nozzle, detectors & other devices for physical damage. Check the extinguishing panel board. Check standby battery. Check the battery charge. Check that cylinder inspection tags are present & updated. Check the pressure of the cylinder. Check solenoid & actuator. Check the detection system. Check the detectors and clean them for proper performance.
Safety Policy: WorkForce shall be provided with proper uniform, hand gloves, face mask, and other safety equipment to be used while duty. Shall take special care to seclude the area of our work by proper partition and provide signboard in the area of work. Clean the area completely after completion of the work and never leave tools, waste, etc. at the worksite. The vendor is solely responsible for any liability that may arise due to the injury sustained to its employees during the course of their work under this agreement. NOTE TO VENDORSAs per the rules, all vendors supplying services in the Emirate of Dubai must have trade license issued by relevant authority in the Emirate of Dubai.Before you apply for any job in the Emirate of Dubai, please make sure to comply with regulatory requirements.Failure to do so can result in stoppage of funds through Escrow Account.HOAM bears no liability towards any payment that is withheld by the Escrow Operator.* b. consider all risks, contingencies and other circumstances relating to the delivery of the Requirements and include adequate provision in its Proposal to manage such risks and contingencies. c. document in its Proposal all assumptions and qualifications made about the delivery of the Requirements, including any assumption that HOAM or a third party wi

تفاصيل الوظيفة

منطقة الوظيفة
دبي الإمارات العربية المتحدة
قطاع الشركة
خدمات الدعم التجاري الأخرى
طبيعة عمل الشركة
غير محدد
نوع التوظيف
غير محدد
الراتب الشهري
غير محدد
عدد الوظائف الشاغرة
غير محدد

هل تحتاج لمساعدة في إضافة الكلمات المفتاحية المناسبة لسيرتك الذاتية؟

اطلب مساعدة الخبراء لكتابة سيرة ذاتية مميزة.

لقد تجاوزت الحد الأقصى لعدد التنبيهات الوظيفية المسموح بإضافتها والذي يبلغ 15. يرجى حذف إحدى التنبيهات الوظيفية الحالية لإضافة تنبيه جديد
تم إنشاء تنبيه للوظائف المماثلة بنجاح. يمكنك إدارة التنبيهات عبر الذهاب إلى الإعدادات.
تم إلغاء تفعيل تنبيه الوظائف المماثلة بنجاح. يمكنك إدارة التنبيهات عبر الذهاب إلى الإعدادات.